jwed b59b5bf6be Spec: proxy_untrusted is not a sufficient outage alarm
Found while implementing the resolver. The spec claimed the difference between "no
client matched this IP" and "this IP is the proxy" made a TrustProxies
misconfiguration one glance to diagnose. That holds only for the case where the
forwarded header arrives and TrustProxies fails to apply it.

If Traefik is misconfigured such that no X-Forwarded-For is sent at all, the
resolver sees a plain unmatched IP and reports no_client — which reads to the
person in front of it as "your device is not on the network", and to an operator
as nothing at all. The alarm is silent in precisely one of the two ways the thing
it guards can break.

Recorded rather than patched, because the fix belongs to Plan 2's health line: it
should show the resolved client IP and say what it is, instead of reporting a
reason code. And the hardware validation step now has to confirm the true client
IP actually arrives — confirming the alarm is quiet is not evidence, since a quiet
alarm is what this blind spot produces.